H97

Malfunction Decision Conditions

  • The rotation speed detected by the Hall IC during fan motor operation is used to determine abnormal fan motor.

Malfunction Caused

  • Operation stops due to short circuit inside the fan motor winding.
  • Operation stops due to breaking of wire inside the fan motor.
  • Operation stops due to breaking of fan motor lead wires.
  • Operation stops due to Hall IC malfunction.
  • Operation error due to faulty outdoor unit PCB.

Troubleshooting

Turn off power supply and rotate fan by hand.
Does fan rotate smoothly?
No
No
Replace fan motor.
Caution For safety reason and to prevent component breakdown, always switch off the power before remove and connect the component.
Yes
If YES (fan rotates smoothly):
Turn power supply on and operate fan.
Does it rotate?
No
If NO (fan does not rotate):
Turn off power supply and disconnect fan motor connector.
Check the fan motor winding resistance at CN-MTR2
Is the winding open / short, resistance value not uniform / very much different?
No
No
Replace
outdoor PCB
Yes
Yes
Replace
fan motor
If YES (fan rotates):
Check the fan motor rotation condition.
Does it have run-stop symptom?
Yes
Yes
Replace
fan motor
No
No
Replace
outdoor PCB